Mounting Type
Mounting Type refers to the method by which an electronic component is attached to a printed circuit board (PCB) or other surface. Common mounting types include:
* Through-hole: Component leads are inserted into holes in the PCB and soldered on the other side.
* Surface-mount: Component is placed on the surface of the PCB and soldered in place.
* Press-fit: Component is pressed into place on the PCB without soldering.
* Socket: Component is inserted into a socket on the PCB, allowing for easy replacement.
The mounting type is determined by factors such as the component's size, shape, and power requirements.
Surface Mount
Package / Case
Package / Case refers to the physical housing or enclosure that encapsulates an electronic component. It provides protection, facilitates handling, and enables electrical connections. The package type determines the component's size, shape, pin configuration, and mounting options. Common package types include DIP (dual in-line package), SOIC (small outline integrated circuit), and BGA (ball grid array). The package also influences the component's thermal and electrical performance.
24-SSOP (0.209, 5.30mm Width)
Number of Pins
Number of Pins: Indicates the number of electrical connections available on the component. These pins are used to connect the component to other components or circuits on a printed circuit board (PCB). The number of pins determines the functionality and connectivity options of the component. It is important to ensure that the component has the correct number of pins for the intended application.
24
Operating Temperature
Operating Temperature is the range of temperatures at which an electronic component can function properly. It is typically specified in degrees Celsius (°C) and indicates the minimum and maximum temperatures at which the component can operate without experiencing damage or degradation. Operating Temperature is an important parameter to consider when designing electronic circuits, as it ensures that the components will function reliably in the intended operating environment.
-40°C~85°C
Packaging
Tape & Reel (TR)
Part Status
Part Status is an electronic component parameter that indicates the availability and production status of a component. It is typically used to inform customers about the availability of a component, whether it is in production, end-of-life, or obsolete. Part Status can also provide information about any restrictions or limitations on the component's use, such as whether it is only available for certain applications or if it has been discontinued.
Obsolete
Moisture Sensitivity Level (MSL)
Moisture Sensitivity Level (MSL) is a measure of the susceptibility of a surface mount electronic component to moisture-induced damage during soldering. It is classified into six levels, from 1 (least sensitive) to 6 (most sensitive). MSL is determined by the materials used in the component's construction, including the solderability of its terminals and the presence of moisture-absorbing materials. Components with higher MSL ratings require more stringent handling and storage conditions to prevent moisture absorption and subsequent damage during soldering.
1 (Unlimited)
Number of Terminations
24
Terminal Finish
Matte Tin (Sn)
Subcategory
Other Analog ICs
Voltage - Supply
4.5V~5.5V
Peak Reflow Temperature (Cel)
260
Supply Voltage
Supply Voltage is the voltage required to power an electronic component. It is typically measured in volts (V) and is specified in the component's datasheet. The supply voltage must be within the specified range for the component to function properly. If the supply voltage is too low, the component may not function at all. If the supply voltage is too high, the component may be damaged.
5V
Reflow Temperature-Max (s)
40
Qualification Status
Not Qualified
Supply Voltage-Max (Vsup)
5.5V
Supply Voltage-Min (Vsup)
4.5V
Analog IC - Other Type
ANALOG CIRCUIT
Supply Current-Max (Isup)
3mA
Length
Length, in the context of electronic components, refers to the physical dimension of a component along its longest axis. It is typically measured in millimeters (mm) or inches (in). Length is a crucial parameter for determining the physical size and space requirements of a component on a printed circuit board (PCB) or other assembly. It also affects the component's electrical characteristics, such as inductance and capacitance, which can be influenced by the length of conductors or traces within the component.
8.2mm
RoHS Status
Non-RoHS Compliant
Description
The MCP3905/06 energy-metering ICs are designed for single-phase, residential energy metering applications. They comply with the IEC 62053 International Energy Metering Specification and legacy IEC 1036/61036/687 Specifications. These ICs provide accurate active (real) power measurement over a wide dynamic range. They feature two 16-bit, delta-sigma ADCs, a programmable gain amplifier (PGA), and an ultra-low drift voltage reference. The MCP3905/06 also include strong output drive for mechanical counters and two-phase stepper motors, as well as a tamper output pin for negative power indication.
Features
Supplies active (real) power measurement for single-phase, residential energy metering
Supports the IEC 62053 International Energy Metering Specification and legacy IEC 1036/61036/687 Specifications
Two multi-bit, Digital-to-Analog Converters (DACs), second-order, 16-bit, Delta-Sigma Analog-to-Digital Converters (ADCs)
0.1% typical measurement error over 500:1 dynamic range (MCP3905)
0.1% typical measurement error over 1000:1 dynamic range (MCP3906)
Programmable Gain Amplifier (PGA) for small-signal inputs supports low-value shunt current sensor
16:1 PGA MCP3905
32:1 PGA MCP3906
Ultra-low drift on-chip reference: 15 ppm/°C (typ.)
Direct drive for electromagnetic mechanical counter and two-phase stepper motors
Low Ipp of 4 mA (typ.)
Tamper output pin for negative power indication
Industrial Temperature Range: -40°C to 85°C
Supplies instantaneous active (real) power on HFOUT for meter calibration
Applications
Single-phase energy meters
Residential energy metering
Industrial energy metering
Power quality monitoring