Factory Lead Time
19 Weeks
Dielectric Material
Perfluoroalkoxy (PFA)
Conductor Material
Copper Alloy, Tinned
Jacket (Insulation) Material
Perfluoroalkoxy (PFA)
Shield Material
Copper, Tinned
Operating Temperature
Operating Temperature is the range of temperatures at which an electronic component can function properly. It is typically specified in degrees Celsius (°C) and indicates the minimum and maximum temperatures at which the component can operate without experiencing damage or degradation. Operating Temperature is an important parameter to consider when designing electronic circuits, as it ensures that the components will function reliably in the intended operating environment.
-70°C~150°C
Part Status
Part Status is an electronic component parameter that indicates the availability and production status of a component. It is typically used to inform customers about the availability of a component, whether it is in production, end-of-life, or obsolete. Part Status can also provide information about any restrictions or limitations on the component's use, such as whether it is only available for certain applications or if it has been discontinued.
Active
Moisture Sensitivity Level (MSL)
Moisture Sensitivity Level (MSL) is a measure of the susceptibility of a surface mount electronic component to moisture-induced damage during soldering. It is classified into six levels, from 1 (least sensitive) to 6 (most sensitive). MSL is determined by the materials used in the component's construction, including the solderability of its terminals and the presence of moisture-absorbing materials. Components with higher MSL ratings require more stringent handling and storage conditions to prevent moisture absorption and subsequent damage during soldering.
1 (Unlimited)
Resistance
Resistance is a measure of the opposition to the flow of electric current in a conductor. It is measured in ohms (Ω). The higher the resistance, the more difficult it is for current to flow. Resistance is caused by the collisions of electrons with atoms and molecules in the conductor. The more collisions that occur, the higher the resistance.
5Ohm
Wire Gauge
Wire gauge is a measure of the thickness of a wire. It is typically expressed in American Wire Gauge (AWG), which is a logarithmic scale where a higher number indicates a thinner wire. The larger the wire gauge, the smaller the diameter of the wire. Wire gauge is important because it affects the current-carrying capacity and resistance of a wire. A thicker wire can carry more current and has less resistance than a thinner wire.
40 AWG
Connector Support Type
WIRE AND CABLE
Impedance
Impedance is a measure of the opposition to the flow of alternating current (AC) in an electrical circuit. It is a complex quantity that has both magnitude and phase. The magnitude of impedance is measured in ohms, and the phase is measured in degrees.
Impedance is determined by the resistance, inductance, and capacitance of the circuit. Resistance is the opposition to the flow of current due to the material of the conductor. Inductance is the opposition to the flow of current due to the magnetic field created by the current. Capacitance is the opposition to the flow of current due to the storage of charge on the plates of a capacitor.
50Ohm
Conductor Strand
7 Strands / 48 AWG
Jacket (Insulation) Diameter
0.014 (0.36mm)
Rated Voltage
Rated Voltage is the maximum voltage that can be applied to an electronic component without causing damage or compromising its performance. It is typically specified in volts (V) and is determined by the component's design and materials. Exceeding the rated voltage can lead to insulation breakdown, overheating, or other failures.
30V
VoP, Velocity of Propagation
70
Length
Length, in the context of electronic components, refers to the physical dimension of a component along its longest axis. It is typically measured in millimeters (mm) or inches (in). Length is a crucial parameter for determining the physical size and space requirements of a component on a printed circuit board (PCB) or other assembly. It also affects the component's electrical characteristics, such as inductance and capacitance, which can be influenced by the length of conductors or traces within the component.
328.1' 100.00m
RoHS Status
ROHS3 Compliant
9440 WH033 OverviewThis product is manufactured by Alpha Wire and belongs to the category of Coaxial Cables (RF). The images we provide are for reference only, for detailed product information please see specification sheet 9440 WH033 or the datasheet in PDF format. As a professional electronic components distributor, Zeano has five million electronic components available. Additionally, we have over 500,000 electronic components in stock ready for immediate shipment. If you have requirements, you can send us a quotation form to get the price of 9440 WH033. We attach great importance to our customers' purchasing experience and are willing to establish a long-term cooperative relationship with you. If you have any questions or requirements, please feel free to contact us.
9440 WH033 More Descriptions
Coaxial Cable Spiral Serve Perfluoroalkoxy 40AWG 0.34mm 30VAC White 99.97m Spool
Coaxial Cable,50 Ohm,10X bend radius, TC,40 AWG White | Alpha Wire 9440 WH033
Micro - Coax, 9440 WHITE 328 FT 40AWG 50OHM PFA Removed 4/21/23
MICRO COAX CABLE, 0.0055MM², WHITE, 100M; Coaxial Cable Type: -; Wire Gauge: 40AWG; Conductor Area CSA: 0.0055mm²; Impedance: 50ohm; Reel Length (Imperial): 328ft; Reel Length (Metric): 100m; Jacket Colour: White; Jacket Material: PFA; Conductor Material: Tinned Copper; No. of Max Strands x Strand Size: 7 x 0.031mm; External Diameter: 0.36mm; Product Range: Micro Coaxial; SVHC: No SVHC (15-Jan-2019)