Factory Lead Time
14 Weeks
Housing Material
Housing Material refers to the material used to construct the outer casing or enclosure of an electronic component.
Thermoplastic
Material - Frame
Polybutylene Terephthalate (PBT)
Material - Blade
Polybutylene Terephthalate (PBT)
Operating Temperature
Operating Temperature is the range of temperatures at which an electronic component can function properly. It is typically specified in degrees Celsius (°C) and indicates the minimum and maximum temperatures at which the component can operate without experiencing damage or degradation. Operating Temperature is an important parameter to consider when designing electronic circuits, as it ensures that the components will function reliably in the intended operating environment.
-13~158°F -25°C~70°C
Series
Series, in the context of electronic components, refers to the arrangement of components in a circuit. When components are connected in series, they form a single path for current to flow through. The total resistance of a series circuit is the sum of the individual resistances of each component. Series connections are often used to control the flow of current in a circuit, as the total resistance can be adjusted by changing the number or type of components in the series.
CF
Size / Dimension
Square - 120mm Lx120mm H
Feature
Auto Restart, Electronic Commutation (EC), Dual Voltage
Part Status
Part Status is an electronic component parameter that indicates the availability and production status of a component. It is typically used to inform customers about the availability of a component, whether it is in production, end-of-life, or obsolete. Part Status can also provide information about any restrictions or limitations on the component's use, such as whether it is only available for certain applications or if it has been discontinued.
Active
Moisture Sensitivity Level (MSL)
Moisture Sensitivity Level (MSL) is a measure of the susceptibility of a surface mount electronic component to moisture-induced damage during soldering. It is classified into six levels, from 1 (least sensitive) to 6 (most sensitive). MSL is determined by the materials used in the component's construction, including the solderability of its terminals and the presence of moisture-absorbing materials. Components with higher MSL ratings require more stringent handling and storage conditions to prevent moisture absorption and subsequent damage during soldering.
Not Applicable
Termination
Termination refers to the electrical characteristics of a component or circuit at its input or output terminals. It describes how the component or circuit interacts with external signals or devices. Termination can involve matching impedance, providing voltage or current regulation, or filtering unwanted signals. Proper termination ensures efficient signal transfer, minimizes reflections, and prevents damage to components. It is crucial for maintaining signal integrity and optimizing circuit performance.
2 Wire Leads
Power (Watts)
Power (Watts) is a measure of the rate at which electrical energy is transferred or consumed. In electronic components, it represents the maximum amount of power that the component can handle without being damaged. It is typically expressed in watts (W) and is determined by factors such as the component's voltage and current ratings, as well as its physical design and materials. Understanding the power rating of a component is crucial for ensuring its safe and reliable operation within a circuit.
3.40W
Voltage - Rated
Voltage - Rated refers to the maximum voltage that an electronic component can withstand without being damaged. It is typically specified in volts (V) and is an important parameter to consider when selecting components for a circuit. Exceeding the rated voltage can lead to component failure, so it is important to ensure that the voltage applied to a component does not exceed its rated voltage.
100/240VAC
Current Rating (Amps)
0.061A
Ingress Protection
IP55 - Dust Protected, Water Resistant
Approval Agency
ATEX, CE, CUR, TUV, UL
Air Flow
90.1 CFM (2.52m3/min)
Noise
Noise in electronic components refers to unwanted electrical or electromagnetic signals that interfere with the desired signal. It can be caused by various factors, such as thermal agitation, shot noise, and flicker noise. Noise is typically measured in decibels (dB) or volts per root hertz (V/√Hz). A higher noise figure indicates a higher level of noise. Noise can degrade the performance of electronic circuits by reducing signal-to-noise ratio (SNR) and increasing errors.
40.2 dB(A)
Voltage Range
Voltage Range is the range of voltages that an electronic component can withstand without being damaged or malfunctioning. It is typically specified in volts (V) and can be either a single value or a range of values. For example, a component with a voltage range of 5V to 12V can withstand voltages between 5V and 12V without being damaged. Exceeding the voltage range can cause the component to fail or malfunction, so it is important to ensure that the voltage applied to a component does not exceed its voltage range.
90V~265VAC
Static Pressure
0.310 in H2O (77.2 Pa)
RoHS Status
ROHS3 Compliant
CF4113MBL-000U-ABD OverviewThis product is manufactured by Sunon Fans, is an electronic component designed as an AC Fan. It has a weight of 0.699lb or 317.06g and features an auto restart function, electronic commutation (EC), dual voltage capability, and a moisture sensitivity level (MSL) that does not apply to it. The power consumption is 3.40W, with a current rating of 0.061A. The cable length measures 330mm, and it uses a ball-type bearing for optimal performance. The fan type is tubeaxial, providing efficient airflow without anyisies of 40.2 dB(A).
CF4113MBL-000U-ABD More Descriptions
EC Fans EC Axial Fan, 120x120x38mm, 100-240VAC, Auto Restart/Special Warranty, IP55/ATEX
AC Fan Ball Bearing 100V to 240V 0.061A 3.4W 3000RPM 90.1CFM 40.2dBA Flange Mount
CF Series 3000 RPM 120 x 120 x 38 mm 90.1 CFM IP55/ATEX 2 Wire EC Axial Fan
AC Fan, 110-230V, Dual Ball, 90CFM, 40dBA, 120x38mm, Wire Leads, EC Fan Series | Sunon Fans CF4113MBL-000U-ABD
Fan 230V 120x38 B L 153m³/h IP55 ATEX