CUI Inc. VMS-300-12-CF

Mfr.Part #:

VMS-300-12-CF

Manufacturer:

Description:
AC/DC CONVERTER 12V 300W

RoHS Status:

RoHS

Datasheet:

Payment:

Payment

Delivery:

Delivery

Quick Request Quote

Do you want a lower wholesale price? Please send us an inquiry, and we will respond immediately.

Latest Posts

A switch solenoid converts electrical energy into mechanical movement by using a simple principle:...
Voltage controlled oscillator takes a voltage (like from a battery) and turns it into...
Types of computer cables: USB cables, HDMI cables, Ethernet cables, power cables,VGA and display
A potentiometer is like a dimmer switch for electronic devices - it controls the...
Security

Buy With Confidence

ISO 9001
ISO 9001
ISO 45001
ISO 45001
ISO 13485
ISO 13485
ISO 14001
ISO 14001
SMTA
ASA

Specifications

Product Details

Product Comparison

Factory Lead Time
23 Weeks
Mount
Chassis Mount
Mounting Type

Mounting Type refers to the method by which an electronic component is attached to a printed circuit board (PCB) or other surface. Common mounting types include: * Through-hole: Component leads are inserted into holes in the PCB and soldered on the other side. * Surface-mount: Component is placed on the surface of the PCB and soldered in place. * Press-fit: Component is pressed into place on the PCB without soldering. * Socket: Component is inserted into a socket on the PCB, allowing for easy replacement. The mounting type is determined by factors such as the component's size, shape, and power requirements.

Chassis Mount
Operating Temperature

Operating Temperature is the range of temperatures at which an electronic component can function properly. It is typically specified in degrees Celsius (°C) and indicates the minimum and maximum temperatures at which the component can operate without experiencing damage or degradation. Operating Temperature is an important parameter to consider when designing electronic circuits, as it ensures that the components will function reliably in the intended operating environment.

0°C~70°C With Derating
Series

Series, in the context of electronic components, refers to the arrangement of components in a circuit. When components are connected in series, they form a single path for current to flow through. The total resistance of a series circuit is the sum of the individual resistances of each component. Series connections are often used to control the flow of current in a circuit, as the total resistance can be adjusted by changing the number or type of components in the series.

VMS-300 (300W)
Published
2012
Size / Dimension
5.00Lx3.20W x 2.00 H 127.0mmx81.3mmx50.8mm
Feature
Adjustable Output, PFC, Remote On/Off, Standby Output, Universal Input
Pbfree Code
yes
Part Status

Part Status is an electronic component parameter that indicates the availability and production status of a component. It is typically used to inform customers about the availability of a component, whether it is in production, end-of-life, or obsolete. Part Status can also provide information about any restrictions or limitations on the component's use, such as whether it is only available for certain applications or if it has been discontinued.

Active
Moisture Sensitivity Level (MSL)

Moisture Sensitivity Level (MSL) is a measure of the susceptibility of a surface mount electronic component to moisture-induced damage during soldering. It is classified into six levels, from 1 (least sensitive) to 6 (most sensitive). MSL is determined by the materials used in the component's construction, including the solderability of its terminals and the presence of moisture-absorbing materials. Components with higher MSL ratings require more stringent handling and storage conditions to prevent moisture absorption and subsequent damage during soldering.

1 (Unlimited)
Applications
Medical
Power (Watts)

Power (Watts) is a measure of the rate at which electrical energy is transferred or consumed. In electronic components, it represents the maximum amount of power that the component can handle without being damaged. It is typically expressed in watts (W) and is determined by factors such as the component's voltage and current ratings, as well as its physical design and materials. Understanding the power rating of a component is crucial for ensuring its safe and reliable operation within a circuit.

300W
Subcategory
Power Supply Modules
Max Power Dissipation
300W
Number of Outputs

Number of Outputs refers to the number of independent output signals or channels that an electronic component can provide. It indicates the capability of the component to drive multiple external devices or circuits simultaneously. A higher number of outputs allows for greater flexibility and connectivity in electronic systems.

1
Approval Agency
CE, cURus, GS
Efficiency
82%
Voltage - Isolation

Voltage - Isolation refers to the maximum voltage that can be applied between two points in an electronic component without causing electrical breakdown. It is a measure of the component's ability to withstand high voltages without allowing current to flow between the points. A higher voltage isolation rating indicates that the component can withstand higher voltages without failing.

4kV
Output Voltage

Output Voltage is the voltage level produced by an electronic component when it is operating. It is typically measured in volts (V) and can be either positive or negative. The output voltage of a component is determined by its design and the input voltage applied to it. For example, a voltage regulator will produce a fixed output voltage regardless of the input voltage, while an amplifier will produce an output voltage that is proportional to the input voltage.

12V
Max Output Current
25A
Voltage - Output 1
12V
Voltage - Input
90V~264VAC
Protections
OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL
Height

Height, in the context of electronic components, refers to the vertical dimension of the component. It is typically measured in millimeters (mm) or inches (in). Height is an important parameter to consider when designing and assembling electronic circuits, as it affects the overall size and form factor of the device. Components with a smaller height are often preferred for applications where space is limited, such as in portable devices or embedded systems.

50.8mm
RoHS Status
RoHS Compliant
Lead Free
Lead Free
VMS-300-12-CF Overview
This product is manufactured by CUI Inc. and belongs to the category of AC DC Converters. The images we provide are for reference only, for detailed product information please see specification sheet VMS-300-12-CF or the datasheet in PDF format. As a professional electronic components distributor, Zeano has five million electronic components available. Additionally, we have over 500,000 electronic components in stock ready for immediate shipment. If you have requirements, you can send us a quotation form to get the price of VMS-300-12-CF. We attach great importance to our customers' purchasing experience and are willing to establish a long-term cooperative relationship with you. If you have any questions or requirements, please feel free to contact us.
VMS-300-12-CF More Descriptions
Switching Power Supplies 300W 12V metal case w/ top fan MED
AC/DC CONVERTER 12V 300W
12 Vdc, 25 A, 300 W
  • Image
    Part Number
    Manufacturer
    Factory Lead Time
    Mount
    Mounting Type
    Operating Temperature
    Series
    Published
    Size / Dimension
    Feature
    Pbfree Code
    Part Status
    Moisture Sensitivity Level (MSL)
    Applications
    Power (Watts)
    Subcategory
    Max Power Dissipation
    Number of Outputs
    Approval Agency
    Efficiency
    Voltage - Isolation
    Output Voltage
    Max Output Current
    Voltage - Output 1
    Voltage - Input
    Protections
    Height
    RoHS Status
    Lead Free
    Max Operating Temperature
    Min Operating Temperature
    Current - Output (Max)
    Minimum Load Required
    Length
    Width
    View Compare
  • VMS-300-12-CF
    VMS-300-12-CF
    23 Weeks
    Chassis Mount
    Chassis Mount
    0°C~70°C With Derating
    VMS-300 (300W)
    2012
    5.00Lx3.20W x 2.00 H 127.0mmx81.3mmx50.8mm
    Adjustable Output, PFC, Remote On/Off, Standby Output, Universal Input
    yes
    Active
    1 (Unlimited)
    Medical
    300W
    Power Supply Modules
    300W
    1
    CE, cURus, GS
    82%
    4kV
    12V
    25A
    12V
    90V~264VAC
    OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL
    50.8mm
    RoHS Compliant
    Lead Free
    -
    -
    -
    -
    -
    -
    -
  • VMS-80-12
    10 Weeks
    Chassis Mount
    Chassis Mount
    0°C~70°C With Derating
    VMS-80 (80W)
    2012
    5.00Lx3.01W x 1.10 H 127.0mmx76.5mmx27.9mm
    Universal Input
    -
    Obsolete
    1 (Unlimited)
    Medical
    80W
    -
    80W
    1
    CE, cURus, TUV
    85%
    5.656kV
    -
    6.66A
    12V
    90V~260VAC
    -
    27.94mm
    RoHS Compliant
    Lead Free
    70°C
    0°C
    6.66A
    No
    127mm
    76.454mm
  • VMS-80-24
    10 Weeks
    Chassis Mount
    Chassis Mount
    0°C~70°C With Derating
    VMS-80 (80W)
    2012
    5.00Lx3.01W x 1.10 H 127.0mmx76.5mmx27.9mm
    Universal Input
    -
    Obsolete
    1 (Unlimited)
    Medical
    80W
    -
    80W
    1
    CE, cURus, TUV
    85%
    5.656kV
    -
    3.33A
    24V
    90V~260VAC
    -
    27.94mm
    RoHS Compliant
    Lead Free
    70°C
    0°C
    3.33A
    No
    127mm
    76.454mm